UPS vs AVR – Which Do I Choose?

Share this article:

Because more than 90% of power related problems for industry are related to voltage sags. It is important to analyze the power prior to choosing a corrective method. There is more up-front capital cost related to an Industrial UPS system, as well as recurring costs. Most of the ups system equipment built for Data Centers does not qualify to correct harsh environment voltage. For that matter, the nature of the loads in a facility requires a totally different sizing method for UPS systems in an industrial setting. For these reasons it is imperative to measure and analyze the loads in the facility, as well as the power to determine the best course of action.

How to Choose Between UPS and an AVR

The Harsh environment in a plant facility requires a robust Industrial UPS solution or an (AVR) Active Voltage Correction Device. The sizing and tolerance of an Industrial UPS System vs. sizing an AVR Voltage Correction device is different. Both require an analysis of the load center and the incoming power to determine the best choice. This is done with a FGC certified meter to capture the load characteristics and power data. This monitoring will specifically pick up issues in the plant affecting equipment. Our national team of installation professionals can provide a turn-key installation proposal that reflect delivery, installation, and electrical inter-connection.

It is not that you should oversize a UPS System for Industrial type loads. It is more that it may not work all together based on the technology. Seek out a qualified contractor to assist in measuring loads. Contact your ICP Representative to discuss the sizing and load calculations for a proper AVR, AVC, or Industrial UPS System.

Pifalls to Installing UPS vs AVR

-Overlooking Inrush currents on mechanical loads leading to overloads

-Expecting a UPS System to support facility loads like a data center

-Not considering temperature environment

-Not considering Air Quality issues for UPS

-Overall technology: inverter-based UPS vs transformer-based UPS

Industrial Clean Power Ready to Assist

 

Voltage Correction is here to help review your power consumption and issues in order to increase efficiency in your facility and correct facility power issues with real solutions. If you’re ready for a product solution, metering, or want to request a site visit,  contact our team  today and let us know how we can help Phone 855-240-6776

 

Connect with Us:

by Tyler Marks 20 February 2025
Using Medium Voltage (MV) with Power Distribution for Industry provides an efficient delivery of High Capacity Power to Manufacturing Facility and Industrial Production Floors. A higher voltage provides a more “efficient” path for “AC Current” to travel to equipment. Large Motors and high inrush starter loads require much more Startup Current, medium voltage power distribution within a plant will provide an efficient capacity of Amperage for this high demand equipment. If production equipment in a Plant operates at lower voltage (LV), the delivery mechanism of higher voltage, closer to the equipment seeking the higher amperage, makes for more capacity available to the loads. This is achieved by the installation of step down function transformers, allowing the medium voltage (MV) to deliver higher capacity amperage “near” the loads. Then step down voltage at or near the equipment to the usable voltage. Benefits of Medium Voltage in a Facility -Higher Amperage Capacity delivered closer to Equipment Seeking Current (Amps). -Less “Current” loss during distribution through plant to various loads. -Lower “Pipe and Wire” costs as higher voltage requires smaller wire size to transmit. -More reliability in overall plant equipment: ie. Affects of power anomalies from lower voltage, sags, surges, failure of Machine Equipment Components. Disadvantages of Medium Voltage in a Facility -Higher cost to Utility for setup -Specialized Maintenance at higher voltage levels -Potential first costs higher for substation and distribution equipment up front, but lower cost of ownership over time. Low Voltage for Industrial Loads Low voltage distribution in a Plant can be installed successfully with a very constant load profile and demand. If there is larger equipment such as motors and processing that cycle on and off with large inrush current demand, this will affect the other areas of the Plant. These “surges” in demand for Current in these high demand inrush devices, can starve or pull down overall voltage in the other areas in the plant electrical distribution, or the entire plant. This will cause Power Supply failures in other equipment which seeks a constant voltage, or will burn components of other equipment due to variable voltage events. Over time this greatly affects a Plant’s Maintenance budget. Benefits of Low Voltage in a Facility -More Familiar Installation and Voltages for most Electrical Contractors. -Immediately available equipment, shorter lead times. -Simpler design and operation of electrical distribution and Electrical One Line. -Less step-down transformers within Facility and Electrical One Line Disadvantages of Low Voltage in a Facility -Exposed to more “Load” created anomalies that may affect other equipment -Limited amperage “Choke Points” for distribution and installation of larger equipment -Current loss from LV distribution through plant. -Susceptible to Inrush Current affect on immediate area or entire facility. -Higher “Pipe and Wire” costs as lower voltage requires higher amperage and larger wiring. Description and Uses of Low (LV) and Medium Voltages (MV) Low Voltage: 1kV - 15kV Typical City Use Power Grid Activities -Residential Use: (120v, 240v) -Commercial Building Use: (120/240v Single/Three Phase, 480v Three Phase) -Manufacturing and Industry: (480v Three Phase) -Localized Utility Distribution: Transformer to Load Medium Voltage: 13.8kV-34.5kV -High Density Data Center Uses -Large Manufacturing, Semiconductor -Motors, Compressors, Large Use Industrial Process -Electrical Utility Distribution, Long and Short Line distances High Voltage: 35kV and larger, 138kV -Long Transmission Lines Substation supply lines from Power Utility Sources -Industrial Processing Facilities, Steel, Mining. -Large transit requirements such as Railways and Commuter trains See your Voltage Correction Specialist to discuss Medium Voltage Power Distribution Options and Corrective Measures for your Facility Power Issues.
by Tyler Marks 20 February 2025
High Density AI compute performance chips like Nvidia Geoforce and now Blackwell B200 chips are requiring up to 300 watt, 400 watt, and 1200 watts. New rounds of chip development are considering up to 3000 watts of power per chip and requiring MEP Engineering design to consider bringing higher voltage closer to the Rack Loads. Why Medium Voltage UPS Systems Higher voltage carried over distances is more efficient than lower voltages carried over the same distance. Medium Voltage (13.8kV, 34.5kV) requires lower current (amps) to achieve the same capacities as low voltage (480v/208v), which exponentially changes the amount of power you can move from Point A to Point B, point B being the Rack loads. 480V Power Distribution for Data Centers In a legacy data center, medium voltage would be delivered to a substation or switchboard on-site. Transformers then step down medium voltage to 480V, which is widely used in data centers for the last 35 years. The typical legacy larger data center delivers 480 volts through the input switchgear, Uninterruptible Power System (UPS) via it’s Maintenance Bypass Switchboard route, and on to a Floor Power Distribution Unit (PDU). At the PDU, the load is stepped down via a internal PDU Transformer to usable 120/208V and 120/240V, which panels of breakers, or sub-feed breakers on the PDU support the actual breakers for servers. Low Voltage UPS Systems are limited to certain capacities to accumulate kW output for larger 2500kW or 5000kVA capacities. See Diagram 1.1
12 August 2024
Explore power backup solutions for Bitcoin mining operations. Learn how to protect your mining equipment from outages and ensure continuous, reliable power.
21 June 2024
Learn how heat domes cause rolling brownouts and affect power stability. Explore strategies to protect your facility from voltage sags and disruptions.
10 June 2024
The plastics industry has a history of complicated manufacturing processes. The procedure to melt plastic stock, transfer it to a die, then hardens to form the product is a process that cannot really be paused or interrupted. This article discusses ways to correct power interruptions for plastic extrusion manufacturing processes. Power Issues Affecting the Plastic… The post UPS Backup Systems for Plastic Extrusion Power Issues appeared first on Industrial Clean Power.
23 May 2024
The ABB PCS 100 Active Voltage Conditioner helps industrial facilities prevent voltage sags and surges, ensuring stable power and equipment protection.
More posts
Share by: