Medium Voltage UPS Systems

2500kVA - 60MVA. 13.8kV - 34.5kV

APPLICATIONS: Facility-WIde UPS , Plant, Labs, Robotics, Process Controls, Semiconductors, Pharmaceuticals, Plastic Extrusion, Metals and Mining.


 SOLVES: All Undervoltage, Overvoltage, Voltage Sags, Surges, unreliable utility voltage and internally-derived Voltage Issues.

Provides battery or other storage runtime for Complete Power Outages.

Technology Choice:   BEST IN CLASS - Complete Facility UPS System. Single Conversion. Generator/ATS Compatibile.

Why? Measures incoming voltage, corrects by Inverter Intercept. Provides runtime via Battery or Ultracapacitors. 

Power Correction Level 1:   +/- 0-4% Variation on Output Power

Input Voltage Tolerance:  Wide Deep Voltage Sags, Complete Outages

     

Sizes: 2500kVA, 5000kVA, 7500kVA, 10,000kVA (10mVA), 12,500kVA, 15,000kVA (15mVA), 17,500kVA, 20,000kVA (20mVA), 22,500kVA, 25,000kVA (25mVA), 27,500kVA, 30,000kVA (30mVA), 32,500kVA, 35,000kVA (35mVA), 37,500kVA, 40,000kVA (40mVA), 45,000kVA (45mVA), 50,000kVA (50mVA), 55,000kva (55mVA), 60,000kVA (60mVA).

Input Voltage: 13.8kVA - 34.5kV


Output Voltage Regulation: +/- 0=3%

Runtimes: Battery or Ultracapacitor to specification,

Generator/ATS Compatible


OPTIONS: Maintenance Bypass


CLASS: UPS, Industrial UPS, AI High Density Data Hall, NVidia Chip, High Density Chiller and Direct Chip Cooling support.


CORRECTS: Voltage Sags and Power Interruptions and Outages


APPLICATIONS: Entire Facility UPS , Plant, Labs, Robotics, Plant and Process, Semiconductors, Pharmaceuticals, Plastic Extrusion, Metals and Mining, All Processes and Controls.


ROI: Reduced PCB and Board Failures, Reduced Downtime, Reduced Maintenance Costs. Typically 3-5 Years.


Medium Voltage UPS for AI High Density Loads

New applications involving high density AI rack loads 100kW - 300kW, and direct to chip cooling methods require intense Power Distribution and Power Sterilization. Cooling delivery systems must now be supported by the conditioned power and backup runtime of an Industrial UPS System. Typical UPS Systems designed for traditional Data Center Construction at small kVA increments require much more Pipe and Wire in between UPS and Switchgear. Floor Power Distribution systems such as PDU's  at smaller sizes require more floor space, and less power distribution.


Newly Designed Medium Voltage UPS Systems and Medium Voltage Power distribution delivered as close to the rack as possible, allows for a highly efficient one line and power delivery. These designs will reduce the efficiency loss of many transformers along the line of distribution. Medium Voltage Switchgear and Power Delivery to a High Density AI Rack load provides smaller wire, less copper installed, lower carbon footprint, and a high efficiency delivery mechanism to maximize footprint, heat creation, and cost of man hour installation.


AC 15 Medium Voltage UPS Models range from 2500kVA increments to 5000kVA increments. Built with highly efficient modules, allowing for building blocks to 10MW, 40MW and 60MW.  UPS sized along with a 10 year battery system protects the High Density AI Data Hall both Electrical and Mechanical  from power quality events, such as deep sags or short-term outages, enabling continuous power supply for high density Data Hall Practices. 




Request Pricing - Brochures - Help!

Get Help with Sizing Your UPS System, Runtimes and Power Requirements for Your Installation

Request a Quote

Ask Us Any Question!

FGC Customer Advantage

Comprehensive Lifetime Service Support for your AVR Equipment

7 x 24 Emergency Service Response

24x7 emergency service Services through FGC Services and Response Platform

Preventative Maintenance Plans Provided by FGC Services

Keep all your systems free of downtime with Preventative Maintenance Programs. 

Plans include Full Service, Preventative Maintenance Plus Emergency Response, and PM Only.

100% parts coverage

Parts coverage inside your warranty period, extended plans available for Annual or Multi-Year Programs

Asset Management Program

Roll all your Critical Assets and Maintenance Programs into one location - Facility Keys Preferred Platform

7x24 Emergency Response


National Service Coverage for Emergency Calls, On-Site Response, and Remediation.

Remote Diagnostic Services for Rapid Response


Uptime assurance

  • Continuous monitoring for early detection of trends and operating anomalies
  • Analysis and interpretation of alarm and status messages


Rapid incident response

  • Automatic transmission of data for analysis
  • Concurrent diagnosis and dispatch of engineer to site
  • Shipment of parts for corrective maintenance


Increased insight and ease of management

  • Notification of operating conditions that may impact system health
  • Periodic trend and analysis reports
  • Integration of remote and on-site services to ensure business continuity